Heating is common in cold regions. A large number of people may think that they should pay attention to the purchase matters when buying heating aluminium central heating radiators, but they will no longer do other management, maintenance, and attention when they buy them home and use them. Here I will tell you about the precautions for heating.
You Should Know The Indoor Temperature Requirements For Heating
In winter, the indoor temperature should be controlled at no less than 18 degrees, and the average indoor temperature should reach 16 degrees. However, for the elderly and children, the standard of 16 degrees is relatively low, but it should not be too high. Too high will make people feel uncomfortable, and the large temperature difference between indoor and outdoor is easy to cause Colds And Other Diseases.
Pay Attention To The Discharge Of Gas Accumulation In The Aluminium Central Heating Radiators
Because the gas accumulation in the heating pipe causes water circulation stagnation, which affects heating, in addition to the exhaust valve on the top floor, a manual air release valve is installed at the end of each group of radiators. The action should be small when releasing air to prevent twisting off, adjust the exhaust hole angle, prevent the heating water from polluting the wall, and tighten the air valve in time when the air and water are mixed.
Pay Attention When Installing The Heater.
When installing the radiator, maintenance should be considered, and the opening area should be suitable for the whole set of radiators to be disassembled and lifted out. And the decorative parts should be movable, so that when there is a problem with the radiator, it can be easily lifted out to expose the entire pipe and air plate. There should be space for disassembly and replacement of valves at the openings of the vertical pipe and branch valves.
Find Out The Reason Why The Aluminium Central Heating Radiators Is Not Hot.
If the overall heat is not hot, the outdoor water inlet and return valves may not be opened. If a single household is partially not hot, it may be caused by the top floor not being vented. If the radiator is half hot and half cold, it is caused by gas gathering at the tail. In short, to ensure the circulation pressure and temperature, the main reason for not being hot is gas blockage, which can be solved by venting.
Special Reminder, Do Not Privately Modify The Heating Pipes
During the installation of the pipe network, the pipes have a certain slope so that the air in the pipes can gather to the top and exhaust in time. Private modification may cause the slope to go wrong, resulting in local air blockage and failure to exhaust. It will not only affect yourself, but also affect the residents of the entire unit.
Pay Attention To The Treatment Of Heated Radiators Bathrooms Leakage
If there is a leak at the connection of the pipe fittings during the heating period, no matter how big or small, it cannot be solved by yourself. You should notify professional maintenance personnel in time, decompress the leak point and then repair it. You must not bring repairs. This will expand the leak point and damage the pipe fittings.
Correct Use Instructions For Heating
- When testing the water, leave someone at home and open the inlet and return valves;
- The air leakage should be in the closed state;
- Do not shake the heater, and the heater and pipeline should not bear weight:
- Non-professionals should not modify the heater;
- The valve should not be opened and closed frequently during the heating season. The valve can only be in the fully open or fully closed state;
- When a leak occurs, the inlet and return valves should be closed immediately.
- Check all interfaces for leaks within three days after stopping heating.
- It is best to maintain steel heaters with full water. The heating inlet and outlet valves should be closed within one day of stopping central heating.
Pay Attention To Common Heating Troubleshooting Methods
- Common faults: The heating is not hot as a whole
Troubleshooting method: Open the inlet and return valves.
- Common faults: The heating is not hot (the valve is open). The heating is not hot halfway. There is a sound of water in the heating.
Troubleshooting method: There may be air in the heating and it needs to be released.
Method 1: First close the water inlet valve, open the air vent valve to exhaust. When water overflows, close the vent valve.
Method 2: Close the water valve 3/4, then close the return valve, release the vent valve, and close the vent valve when water overflows.
Good reminder: After operation, if the fault still cannot be eliminated, notify the maintenance personnel c. Common faults: The heating pipeline temperature is not enough and the room temperature is too low.
Troubleshooting method: low inlet water temperature, increase the inlet water temperature,
Blute reminder: the property will check the system,
- Common faults: water leakage inside the inlet and return valves (close to the heating direction).
Troubleshooting method: close the inlet and return valves.
Blute reminder: promptly notify the installation team for repairs
- Common faults: water leakage outside the inlet and return valves (close to the main road) Troubleshooting method: notify the property to close the system valve.
Learn To Use Resources
If you encounter radiator quality problems, or installation leakage problems, and you are not good at solving them yourself, you can contact the property, radiator installer, radiator buyer, HVAC engineer, etc. as soon as possible for detailed consultation or request for resolution.
Combining the above heating precautions, I would like to remind everyone that before purchasing a radiator, it is best to make a detailed understanding. Please look for well-known brands to avoid unnecessary trouble for you.